相信很多人都看了很多关于路由器配置方面的知识,在路由配置中也会出现很多问题,笔者某次配置了一个AM模块。出现了一个奇怪的问题。路由器配置好后,拨入时没有Modem拨号声。只有电话的声。并且音指示灯也不亮。当笔者拔下模块上的电话线时。指示灯亮了。
路由器配置
- 620#sh run
- Building configuration...
- Current configuration : 866 bytes
- !
- version 12.2
- service timestamps debug uptime
- service timestamps Jog uptime
- no service password-encryption
- !
- hostname2620
- enable secret 5 $1$pUrf$9xGOg.zyxKawi9NljLHHr1
- usernameuser password 0 Cisco
- ip subnet-zero
- !
- !
- no ip DOmain-lookup
- !
- !
- !
- !
- interface FastEthernet0/0
- ip address 136.0.0.254255.255.0.0
- duplex auto
- speed auto
- !
- interface Group-Async1
- ip unnumbered FastEthernet0/0
- encapsulation ppp
- async default routing
- async mode interactive
- peer default ip address pool lab
- ppp authentication chap
- group-range 33 48
- !
- !
- ip classless
- no ip http server
- ip pim bidir-enable
- !
- !
- line con 0
- password cisco
- line 33 48
- login local
- modem InOut
- autocommand ppp
- transport input all
- autoselect ppp
- stopbits 1
- flowcontrol hardware
- line aux0
- line vty 0 4
- password Cisco
- login
- !
- no scheduler allocate
- end
诊断过程
笔者仔细检查路由器配置文件,发现缺少ip pool,加上ip local pool lab(start ip addr)(stop ip addr),没有效果。后来笔者想到拨号采用的都是模拟信号,与接地有很大关系。没自动应答:多半是接地问题。所以直接把路由器上的接地螺钉,用一根导线接到防静电地板下面的铁支柱上,问题解决了。
排除心得
路由器标准接地的方法是在铺设电源线的时候放置一根地线,然后路由器的外壳接到地线上去就好?,笔者估计原来负责网络系统搭建的厂商采用的电源线忽略了地线,否则也不会出现这样的问舰。接路由器电源的时候如果有地线,一般不需要我们再接地了。